25 resultados para Ophthalmic Optics

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metrology of XUV beams (X-ray lasers, high-harmonic generation and VUV free-electron lasers) is of crucial importance for the development of applications. We have thus developed several new optical systems enabling us to measure the optical properties of XUV beams. By use of a Michelson interferometer working as a Fourier-transform spectrometer, the line shapes of different X-ray lasers have been measured with a very high accuracy (Deltalambda/lambdasimilar to10(-6)). Achievement of the first XUV wavefront sensor has enabled us to measure the beam quality of laser-pumped as well as discharge-pumped X-ray lasers. A capillary discharge X-ray laser has demonstrated a very good wavefront allowing us to achieve an intensity as high as 3x10(14) W cm(-2) by focusing with a f=5 cm mirror. The sensor accuracy has been measured using a calibrated spherical wave generated by diffraction. The accuracy has been estimated to be as good as lambda/120 at 13 nm. Commercial developments are underway. At Laboratoire d'Optique Appliquee, we are setting up a new beamline based on high-harmonic generation in order to start the femtosecond, coherent XUV optic .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To separately investigate the impact of simulated age-related lens yellowing, transparency loss and refractive error on measurements of macular pigment (MP) using resonance Raman spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the quality of referrals from community optometrists in the northeast of Scotland to the hospital glaucoma service before and after the implementation of the new General Ophthalmic Services (GOS) contract in Scotland. Methods: Retrospective study encompassing two 6-month periods, one before the implementation of the new GOS (Scotland) contract in April 2006 (from June to November 2005), and the other after (from June to November 2006). The community optometrist referral forms and hospital glaucoma service notes were reviewed. Comparisons were performed using the t-test and ?- test. Results: In all, 183 referrals were made during the first 6-month period from June to November 2005, and 120 referrals were made during the second 6-month period from June to November 2006. After the introduction of the new GOS contract, there was a statistically significant increase in true-positive referrals (from 18.0 to 31.7%; P=0.006), decrease in false-positive referrals (from 36.6 to 31.7%; P=0.006), and increase in the number of referrals with information on applanation tonometry (from 11.8 to 50.0%; P=0.000), dilated fundal examination (from 2.2 to 24.2%; P=0.000), and repeat visual fields (from 14.8 to 28.3%; P=0.004) when compared to the first 6-month period. However, only 41.7% of referrals fulfilled the new GOS contract requirements, with information on applanation tonometry the most commonly missing. Conclusions: After the implementation of the new GOS (Scotland) contract in April 2006, there has been an improvement in the quality of the glaucoma referrals from the community optometrists in the northeast of Scotland, with a corresponding reduction in false-positive referrals. Despite the relatively positive effect so far, there is still scope for further improvement. © 2009 Macmillan Publishers Limited All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Semiclassical nonlocal optics based on the hydrodynamic description of conduction electrons might be an adequate tool to study complex phenomena in the emerging field of nanoplasmonics. With the aim of confirming this idea, we obtain the local and nonlocal optical absorption spectra in a model nanoplasmonic device in which there are spatial gaps between the components at nanometric and subnanometric scales. After a comparison against time-dependent density functional calculations, we conclude that hydrodynamic nonlocal optics provides absorption spectra exhibiting qualitative agreement but not quantitative accuracy. This lack of accuracy, which is manifest even in the limit where induced electric currents are not established between the constituents of the device, is mainly due to the poor description of induced electron densities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on surgical decision making and risk management usually focuses on peri-operative care, despite the magnitude and frequency of intra-operative risks. The aim of this study was to examine ophthalmic surgeons' intra-operative decisions and risk management strategies in order to explore differences in cognitive processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corneal endothelial cells from normal and traumatized human, primate, cat and rabbit eyes were studied by specular microscopy. Morphometric analysis was performed on micrographs of corneal endothelium using a semi-automated image analysis system. The results showed that under normal conditions the corneal endothelium of all four species exhibit major morphological similarities (mean cell areas: human 317 +/- 32 microns 2, primate 246 +/- 22 microns2, cat 357 +/- 25 microns 2, rabbit 308 +/- 35 microns 2). The normal corneal endothelium in man was found to be more polymegethous than that of the other species. Trauma to cat, primate and human corneas resulted in a long-term reduction in endothelial cell density and enhanced polymegethism. In contrast, the reparative response of the rabbit ensured the reformation of an essentially normal monolayer following injury. Endothelial giant cells were a normal inclusion in the rabbit corneal endothelium but were only significant in cat, primate and man following trauma. The presence of corneal endothelial giant cells in amitotic corneas may therefore represent a compensatory response in the absence of mitotic potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simulation of open quantum dynamics has recently allowed the direct investigation of the features of system-environment interaction and of their consequences on the evolution of a quantum system. Such interaction threatens the quantum properties of the system, spoiling them and causing the phenomenon of decoherence. Sometimes however a coherent exchange of information takes place between system and environment, memory effects arise and the dynamics of the system becomes non-Markovian. Here we report the experimental realisation of a non-Markovian process where system and environment are coupled through a simulated transverse Ising model. By engineering the evolution in a photonic quantum simulator, we demonstrate the role played by system-environment correlations in the emergence of memory effects.